PRODUCT SAFETY SERVICING GUIDELINES FOR AUDIO-VIDEO PRODUCTS
3828VD0205B CH-FLAT - SAFETY
ii
X-Radiation
To prevent possible exposure to x-radiation caused by excessive CRT
anode voltage, the CH-Flat chassis incorporate a “High Voltage
Shutdown” circuit. This circuit senses the level of a flyback pulse
from the “Flyback Transformer” representative of the actual high
voltage on the CRT anode. When this level exceeds a predetermined
voltage, the circuit shuts down the TV set, preventing further gen-
eration of anode voltage.
Shutdown Circuit Operation
(Refer to Figure below)
The flyback pulse voltage from pin 6 of TX3201 (Flyback Trans-
former) is peak detected (rectified) by the action of diode DX3001
and capacitor C3003. This form a DC voltage appearing on C3003
representative of the CRT anode voltage (HV) produced by TX3201.
This voltage is divided down by precision resistors RX3004, RX3005,
RX3006 and RX3007. This lower voltage appears on the zener diode
ZD3000; when this voltage exceeds by 3.5 Vdc the “zener voltage”
the HV shutdown occurs (pin 29 of ICX2200).
CRT Anode High Voltage Measurement Procedure
Each CRT screen size has it’s own safe operating anode and shut-
down voltage. Critical safety component (designated with an ‘X’ in
the component designator) are designed to operate the CRT at a
safe operating anode voltage and provide proper shutdown thresh-
olds. If replacement of any of these components are deemed neces-
sary, it is important to use original type Zenith components. After
replacement is made, confirm proper anode voltage using the fol-
lowing procedure.
Measurement of the CRT anode voltage must be performed using a
high impedance-high voltage meter, with no raster on the screen,
and operating at nominal horizontal frequency, 15.75 Khz (NTSC
signal).
After discharging the CRT, connect a high impedance-high voltage
meter to the CRT anode. Turn the television ‘on’ and confirm a good
signal is being displayed. Reduce Brightness and Contrast settings
until the picture is well extinguished.
Observe the anode voltage meter reading and compare with the
table below for the proper CRT screen size. If the voltage reading
is higher than the maximum, verify circuit component values and
proper operation.
CRT Screen Size Nominal Anode Voltage (KV) Max. Shutdown Voltage (KV)
20" 26+/-1.0 32
CRT Anode Volta
g
e
HV SHUTDOWN PROCEDURE.
·After discharging the CRT, connect a high impedance-high volt-
age meter to the CRT anode
·Access Video Menu and adjust Brightness and Contrast controls
for minimum screen luminance (beam current to 0 mA).
·Wait until the Video Menu or display disappear.
·Connect a variable Resistor (1 MW) between ground and junc-
tion of RX3754 and RX3755, and decrease slowly the resistance
value until shutdown occurs.
·Measure High Voltage shutdown.
Fly-Back Transformer CX3215
Deflection Yoke CX3216
CX3203 RX3753
CX3204 RX3754
CX3205 RX3755
CX3206 RX3756
CX3207
COMPONENTS WITH ANY INFLUENCE IN HV INCREAS
E
Flyback Pulse
IN
RX3209
C3003
DX3001
RX3007
RX3006
RX3005
C3002
ZD3000
R3003
D3002
RM3002
C3001
RM3001
SHUTDOWN
TO PIN 29
ICX2200
Of TX3201
From Pin 6
OUT
RX3004